Basic Info.
Nature of Source Flow
Active Inverter
Grid Type
off-Grid Inverter
Circuit Topologies
Half-Bridge Type
Nature of Wave String
Sine Wave Inverter
Product Name
1000W off Grid Low Frequency Inverter with L
Small Order for Testing
Acceptable
Frequency
50Hz/60Hz(Atomatic Detection)
Specification
375*130*190MM
Product Description
1000W White Off Grid Low Frequency Inverter
Main features:
1.1kw~6kw optional, 12V / 24V / 48VDC optional
2. Max. Charge current 65A.
3. Pure sine wave.
4. Inbuilt pure copper transformer
5. Support inductive load
6. Automatic three-stage battery charger (bulk, absorption, float)
7. With 150cm battery cable
8. Support generator
9. Support solar system
10. Remote control / RS232 optional
11. Pure sine-wave output, can be used with diffent domestic appiance TV, refrigerator, fan, air conditioner induvtion cooker, micro-wave oven etc
12. Superior performance from CPU control technology
13. Wide range of input voltage, accurate output, AVR function
14. Inner-equipped protection for over-load, short-circuit, over-voltage, low-voltage over-heating etc.
15. Easy to check with UPS condition with consice LED indication that can be upgraded To LCD
16. Generator compatibly and external battery connection achievable
17. Intelligent battery management with protection against over-charged and over-discharged etc.
Model No. | TYNF1000W | TYNF1000W | TYNF2000W | TYNF2000W | TYNF3000W | TYNF3000W | TYNF3000W | TYNF5000W | DX6000W | TYNF8000W | TYNF10000W |
| DC12V | DC24V | DC12V | DC24V | DC12V | DC24V | DC48V | DC48V | DC48V | DC96V | DC96V |
1.AC Mode Specifications: |
Input wave form | pure sine wave |
Input voltage | 220Vac |
Low voltage cut off | 145Vac±4% | 165Vac±4% |
Low voltage recover | 155Vac±4% | 175Vac±4% |
High voltage cut off | 285Vac±4% | 265Vac±4% |
High voltage recover | 275Vac±4% | 255Vac±4% |
Frequency | 50Hz/60Hz(Atomatic detection) |
Output wave form | pure sine wave |
Overload protection | alarm |
Short circuit protection | trip |
Efficiency | >95% |
Transfer current | 10A | 30A | 60A |
Transfer time DC TO AC | 10ms |
Transfer time AC TO DC | 10ms |
2.Inverter Mode Specifications: |
Rated power | 1000W | 2000W | 3000W | 5000W | 6000W | 8000W | 10000W |
Power factor | 0~1.0 |
Output voltage | 220Vac |
Frequency | 50Hz ± 0.3Hz |
Automatic tracking the main frequency | Yes(start from the first connection)50Hz @48-54Hz |
60Hz @58-64Hz |
Inputvoltage range | ±10% rms | (-25%/+20%) rms |
Efficiency | >80% |
Overload protection | (110%<load<125%) ±10%: 30S cut off output voltage |
(SMPS load) | (125%<load<150%) ±10%:cut off output voltage at once |
Peak Capacity | 2000VA | 4000VA | 6000VA | 10000VA | 12000VA | 16000VA | 20000VA |
Short circuit protection | Yes |
Input voltage | 12V/24V | 12V/24V/48V/96V |
Min DC voltage | 10V/20V | 10V/20V/40V/80V |
Undervoltage warning | 10.5Vdc ± 0.3Vdc (12V battery) | 10.5Vdc ± 0.3Vdc (12V battery)/42Vdc±1.2Vdc(48V battery) |
21.0Vdc ± 0.6Vdc (24V battery) | 21.0Vdc ± 0.6Vdc (24V battery)/84Vdc±2.4Vdc(96V battery) |
DC input too low, | 10.0Vdc ± 0.3Vdc(12V battery) | 10.0Vdc ± 0.3Vdc(12V battery)/40.0Vdc±1.2Vdc(48V battery) |
Automatic cut off | 20.0vdc± 0.6Vdc (24V battery) | 20.0vdc± 0.6Vdc (24V battery)/80.0Vdc±2.4Vdc(96V battery) |
input voltage warning &cut off | 15Vdc ± 0.3Vdc (12V battery) | 15Vdc ± 0.3Vdc (12V battery)/30Vdc ± 0.6Vdc(24V battery) |
30Vdc ± 0.6Vdc(24V battery) | 60Vdc±1.2Vdc(48V battery)/120Vdc±2.4Vdc(96V battery) |
Save power | load≤25W |
3.Charger Mode Specifications: |
Chargering current | 30A | 15A | 50A | 25A | 50A | 25A | 15A | 15A | 15A | 15A | 15A |
Chargering current correction | ± 5Adc |
Battery initial voltage | 0 -13.7 Vdc |
Charger short circuit protection | trip |
Overcharger protection | V ≥14.7Vdc / 30.4Vdc, every half second sounds |
4.Charging Rules: |
Three Phases | constant current chargering→constant voltage phase→float |
5.Monitor |
Computer Monitor | RS232 |
6.Protection |
Low Voltage | LCD show low battery alarm |
High Voltage | alarm |
Inverter Mode overload | shut-down protection |
Over Temperature | Heatsink temperature.≥90ºC,shut-down protection |
7.Physical |
Operate Temperature Range | 0°C to 40°C |
Store Temperature | -15ºC ~ 60ºC |
Operate Humidity | 5% to 95% |
Noise | 60dB max |
Cooling | fan in ventiltation conditions |
Address:
No. 619 Youyi Building, No. 8 Yongfu Road, Yuexiu District, Guangzhou, Guangdong, China
Business Type:
Trading Company
Business Range:
Electrical & Electronics
Company Introduction:
Our company supplies different kinds of products. High quality and favorable price. We′re pleased to get your Inquiry and we will come back to as soon as possible. We stick to the principle of "quality first, service first, continuous improvement and innovation to meet the customers" for the management and "zero defect, zero complaints" as the quality objective.